The Ability of 67Ga Scintigraphy to Detect Trichinella spiralis
PDF
Cite
Share
Request
Original Investigation
VOLUME: 32 ISSUE: 3
P: 221 - 224
September 2008

The Ability of 67Ga Scintigraphy to Detect Trichinella spiralis

Turkiye Parazitol Derg 2008;32(3):221-224
1. Dokuz Eylül Üniversitesi Tıp Fakültesi, Parazitoloji Anabilm Dalı, İzmir, Türkiye
2. Dokuz Eylül Üniversitesi Tıp Fakültesi, Nükleer Tıp Anabilim Dalı, İzmir, Türkiye
3. Dokuz Eylül Üniversitesi Tıp Fakültesi, Deney Hayvanları Anabilim Dalı, İnciraltı, İzmir, Türkiye
No information available.
No information available
Received Date: 12.12.2007
Accepted Date: 14.04.2008
PDF
Cite
Share
Request

ABSTRACT

To assess the value of 67Ga scintigraphy in the lesions of Trichinella spiralis, an animal model was developed. Three infected and five healthy animals were enrolled in this study. After the injection of 7.4 MBq (200 Ci) 67Ga citrate intravenously, static images from whole body were obtained at 24th, 48th and 72nd hours Visual and semiquantitative analyses were performed. In semiquantitative analysis, activity counts were calculated over the whole body, diaphragm, neck muscles and extremities muscles of all animals. Between the infected animals and control group, mean bodies activity ratios were compared as visually and statistically. 67Ga scintigraphy can’t successfully demonstrate the lesions of Trichinella spiralis.

Keywords:
Trichinella spiralis, Gallium-67 scintigraphy, infection